Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

Fluke 789 Procesmeter

FLUKE DANMARK A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
3977194
7898100542
-
Discount code:
UNSPSC Code:
Customs code:
80160869054
41113630
90303310
The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals, combining the functionality of a loop calibrator with the power of a digital multimeter. By equipping the 789 with a temperature measurement module and the wireless data logging capabilities of Fluke Connect™ with ShareLive™ video call (sold separately), process technicians can now do a lot more while carrying a lot less. And with its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you. Includes: AC175 Alligator Clips Four (4) AA 1.5 V alkaline batteries (installed) TL71 safety-designed test lead set Specifications Current measurement Range 0-1 A AC or DC Resolution 1 mA Accuracy 0.2% + 2 LSD (DC) Range 0-30 mA Resolution 0.001 mA Accuracy 0.05% + 2 lSD Current sourcing Range 0-20 mA or 4-20 mA Resolution 0.05% of span Drive capability 24 V Compliance or 1200 Ω @ 20 mA Frequency to 19.999 kHz, 0.005% + 1 LSD Continuity Beeps for resistance < 100 Ω Voltage measurement Range 0-1000 V AC (true-rms) or DC Resolution 0.1 mV to 1.0 V Accuracy 0.1% Rdg + 1 LSD (VDC) Resistance measurement to 40 MΩ, 0.2% + 1 LSD Diode test 2.0 V shoes diode voltage drop Display current and % of span Yes Auto Step, Auto Ramp Yes

None

;