Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

S803PV-SP32 High Performance MCB

ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
2CCF019615R0001
7822217773
-
Discount code:
UNSPSC Code:
Customs code:
80080800060
39121603
85362020
The S803PV-SP32 is a 3-pole High Performance Circuit breaker for photovoltaics (DC) with B-characteristic, with cage terminal and a rated current of 32 A. It is a current limiting device with a maximum breaking capacity of 5kA at 1200V. It can be used for voltages up to 1200V DC. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S803PV-SP32 complies with IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S803PV-SP32 more comfortable. Due to the fast arc extinction of S803PV-SP32 your application will be secured.
Voltage typeDC
Built-in depth111
Rated current32
Rated voltage1500
Frequency0 - 0
Release characteristicB
Rated insulation voltage Ui1500
Current limiting class3
Over voltage category3
Pollution degree2
Width in number of modular spacings3
Degree of protection (IP)IP20
Number of protected poles3
Concurrently switching N-neutralNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50
Connectable conductor cross section multi-wired0 - 70
Ambient temperature during operating-25 - 60
Additional equipment possibleNo
Number of poles (total)3
Rated short-circuit breaking capacity Icn EN 60898 at 400 V5
Rated short-circuit breaking capacity Icn EN 60898 at 230 V5
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V5
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V5
Rated impulse withstand voltage Uimp8
;