Circuit breaker 400V 10KA, 4-pole, C, 8A
SIEMENS A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
5SL4408-7
7822212260
-
Discount code:
UNSPSC Code:
Customs code:
8008043810315
39121603
85362010
RC unit, 3-pole, type AC, In: 63 A, 300 mA, Un AC: 400 V The RCD is the residual current device for touch protection. The patented residual current protective devices from Siemens are an important component of the SENTRON protective devices for electrical installations, as they prevent life-threatening electrical accidents by safely disconnecting hazardous residual currents through grounding. Electrically ignited fires can be prevented as they occur. Whether the problem is direct contact with energized operating parts or indirect contact with equipment, protection is achieved primarily by rapid shutdown.
Voltage type | AC |
---|---|
Built-in depth | 70.0 |
Rated current | 8 |
Rated voltage | 400 |
Release characteristic | C |
Current limiting class | 3 |
Over voltage category | 3 |
Pollution degree | 2 |
Width in number of modular spacings | 4 |
Degree of protection (IP) | IP20 |
Number of protected poles | 4 |
Concurrently switching N-neutral | No |
Suitable for flush-mounted installation | No |
Connectable conductor cross section solid-core | 0.75 - 25.0 |
Connectable conductor cross section multi-wired | 0.75 - 25.0 |
Additional equipment possible | Yes |
Number of poles (total) | 4 |
Rated short-circuit breaking capacity Icn EN 60898 at 400 V | 10.0 |
Rated short-circuit breaking capacity Icn EN 60898 at 230 V | 10.0 |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V | 10.0 |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V | 10.0 |