Fluke 1550C isolations modstandstester (5kV)
FLUKE DANMARK A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
3665021
7898101318
-
Discount code:
UNSPSC Code:
Customs code:
80160869087
41113623
90303310
Evaluate the trends, eliminate the doubt
The Fluke 1550C insulation resistance tester offers digital insulation testing up to 5 kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables.
Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1550C is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
Features include:
Test voltages to up 5 kV
CAT III 1000 V, CAT IV 600 V safety rating
Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
Long battery life gives the user over 750 tests between charges
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
Guard system eliminates the effect of surface leakage current on high-resistance measurements
Large digital/analog LCD for easy viewing
Capacitance and leakage current measurement
Ramp function for breakdown testing
Resistance measurements up to 2 TΩ
Timer settings up to 99 minutes for timed tests
None