Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

S803S-C6 High Performance MCB

ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
2CCS863001R0064
7822216279
-
Discount code:
UNSPSC Code:
Customs code:
80080800060
39121603
85362020
The S803S-C6 is a 3-pole High Performance Circuit breaker with C-characteristic, with cage terminal and a rated current of 6 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S803S-C6 complies with IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S803S-C6 more comfortable. Due to the fast arc extinction of S803S-C6 your application will be secured.
Voltage typeAC/DC
Built-in depth88.5
Rated current6
Rated voltage400
Frequency50 - 50
Release characteristicC
Rated insulation voltage Ui690
Current limiting class3
Over voltage category3
Pollution degree2
Width in number of modular spacings3
Degree of protection (IP)IP20
Number of protected poles3
Concurrently switching N-neutralNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50
Connectable conductor cross section multi-wired0 - 70
Ambient temperature during operating-25 - 60
Additional equipment possibleYes
Number of poles (total)3
Rated short-circuit breaking capacity Icn EN 60898 at 400 V25
Rated short-circuit breaking capacity Icn EN 60898 at 230 V25
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V50
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V50
Rated impulse withstand voltage Uimp8
;