SINAMICS V90, WITH PROFINET INPUT: 3AC 200-240V -15%/+10% 11.0A 45-66HZ OUTPUT: 0-INPUT V 10.6A 0-330HZ, IP20 MOTOR:1.5KW FRAME SIZE D
Siemens
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
6SL3210-5FB11-5UF0
7865361385
-
Discount code:
UNSPSC Code:
Customs code:
80080433792
26101109
85044084
SINAMICS V90, WITH PROFINET INPUT: 3AC 200-240V -15%/+10% 11.0A 45-66HZ OUTPUT: 0-INPUT V 10.6A 0-330HZ PROTECTION: IP20 MOTOR:1.5KW FRAME SIZE D, 95X170X195(WXHXD)
Width | 95.0 |
---|---|
Height | 170.0 |
Depth | 195.0 |
Number of digital inputs | 4 |
Number of digital outputs | 2 |
Supporting protocol for LON | No |
Number of HW-interfaces USB | 1 |
Supporting protocol for TCP/IP | No |
Supporting protocol for ASI | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for KNX | No |
Supporting protocol for Modbus | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for other bus systems | No |
Degree of protection (IP) | IP20 |
With PC connection | Yes |
Supporting protocol for SERCOS | No |
Supporting protocol for INTERBUS-Safety | No |
Mains voltage | 200 - 240 |
4-quadrant operation possible | Yes |
Number of interfaces PROFINET | 2 |
Type of converter | U converter |
Number of phases output | 3 |
Number of phases input | 3 |
Integrated breaking resistance | Yes |
Application in industrial area permitted | No |
Application in domestic- and commercial area permitted | Yes |
Relative symmetric net voltage tolerance | -15 |
Relative symmetric net frequency tolerance | -15 |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for PROFINET IO | Yes |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Max. output voltage | 212 |
Nominal output current I2N | 10.6 |
Supporting protocol for BACnet | No |