TiS60+ Thermal Camera
FLUKE DANMARK A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
5133402
7898109860
-
Discount code:
UNSPSC Code:
Customs code:
80190777
45121504
90251920
Key Features TiS60+
Infrared resolution 320 x 240 (76,800 pixels)
IFOV with standard lens (spatial resolution) 1.86 mRad, D:S 532:1
Field of view 34.1 °H x 25.6 °V
Minimum focus distance 46 cm (18 in)
Focus system Fixed
Wireless connectivity Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN
(where available)
Fluke™ Connect app compatible Yes
IR Fusion™ technology Yes
AutoBlend™ mode Yes
Picture-In-Picture (PIP) Yes
Ruggedized display 3.5 inch (8.9 cm landscape) 320 x 240 LCD
Ergonomic design Designed for one-handed use
Thermal sensitivity (NETD)** ≤ 0.045 °C at 30 °C target temp (45 mK)
Level and span Smooth auto and manual scaling
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.5 °C (4.5 °F)
Minimum span (in auto mode) 5 °C (9.0 °F)
Built-in digital camera (visible light) 5MP
Frame rate < 9 Hz or 30 Hz
Laser pointer Yes
Data storage and image capture
Extensive memory options Internal 4GB memory and 4GB micro SD card
Image capture, review, save mechanism One-handed image capture, review, and save capability
Image file formats Non-radiometric BMP or JPEG or fully-radiometric is2
Memory review Yes
Software Fluke Connect desktop software—full analysis and reporting software with access to the
Fluke Connect system
Analyze and store radiometric data on a PC Yes
Export file formats with Fluke Connect
software is2, BMP, GIF, JPEG, PNG, TIFF
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth
headset required (sold separately)
IR-PhotoNotes Yes—3 images
Auto capture (temperature and interval) Yes
AC operation AC operation with included power supply (100 V ac to 240 V ac, 50/60 Hz)
Temperature range
(not calibrated below -10 °C) -20 °C to 400 °C (-4 °F to 752 °F)
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 %, non-condensing
Center-point temperature measurement Yes
Spot temperature Hot and cold spot markers
User-definable spot markers 3
User defined measurement boxes Expandable-contractible measurement box
Hard case Rugged hard carrying case with soft transport bag, including adjustable strap
Safety standards IEC 61010-1: Overvoltage category II, Pollution Degree 2
Electromagnetic combability IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
None