[4042948806272] circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole line protection ETU350 LSI In=250A overload protection Ir=100A. Image #0
[4042948806272] circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole line protection ETU350 LSI In=250A overload protection Ir=100A. Image #1
[4042948806272] circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole line protection ETU350 LSI In=250A overload protection Ir=100A. Image #2
[4042948806272] circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole line protection ETU350 LSI In=250A overload protection Ir=100A. Image #0
[4042948806272] circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole line protection ETU350 LSI In=250A overload protection Ir=100A. Image #1
[4042948806272] circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole line protection ETU350 LSI In=250A overload protection Ir=100A. Image #2

[4042948806272] circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole line protection ETU350 LSI In=250A overload protection Ir=100A.

  • EAN no.: 4042948806272
  • LM no.: 4042948806272
  • Supplier: SIEMENS A/S
Must login for adding to cart

Description

Type no.: 3VA2325-5HN32-0AA0

Promotion code: 8008043930274

UNSPSC (v. 19.0501): 39121601

HS Code: 85362090

circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In nut keeper kit 3VA2 molded-case circuit breaker with 8-series ETU for system protection. As an important element of SENTRON protective components for industrial and infrastructure applications, the 3VA molded-case circuit breakers from Siemens provide effective plant, starter and motor protection thanks to reliable shutdown in the event of an overload or short circuit. The 3VA molded-case circuit breakers set new standards in flexibility and the variety of modular accessories available. Standardized accessories for several sizes across all series of the 3VA1 and 3VA2 molded-case circuit breakers. Key features of this version of the 3VA molded-case circuit breaker: 1. Compact design. 2. Available as version for plant protection and generator protection. 3. Available as 3-pole and 4-pole version. 4. Four breaking capacity classes from 55 kA to 150 kA at 415 V. 5. Depending on the size: Rated current 25 A. 630 A. 6. Can be installed fixed, in plug-in design or as withdrawable version. 7. The series has a solid-state overcurrent trip unit. 8. Integrated display for measured values. 9. Integrated measuring function and optional communication connection via Modbus TCP, Modbus RTU, PROFINET and PROFIBUS. 10. Modular and easy-to-fit internal accessories with wide range of functions. www.siemens.de/3VA. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.

Specifications

Motor drive optional
TRUE
Overload release current setting
100 - 250
Integrated earth fault protection
FALSE
Suitable for DIN rail (top hat rail) mounting
TRUE
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Adjustment range short-term delayed short-circuit release
375 - 2500
Adjustment range undelayed short-circuit release
3000 - 3000
With switched-off indicator
FALSE
Type of electrical connection of main circuit
Screw connection