[4047621014524] Circuit breaker S3 system protection UL 489 CSA C22.2 No. 5-02 short-circuit release 650 A Image #0
[4047621014524] Circuit breaker S3 system protection UL 489 CSA C22.2 No. 5-02 short-circuit release 650 A Image #1
[4047621014524] Circuit breaker S3 system protection UL 489 CSA C22.2 No. 5-02 short-circuit release 650 A Image #2
[4047621014524] Circuit breaker S3 system protection UL 489 CSA C22.2 No. 5-02 short-circuit release 650 A Image #0
[4047621014524] Circuit breaker S3 system protection UL 489 CSA C22.2 No. 5-02 short-circuit release 650 A Image #1
[4047621014524] Circuit breaker S3 system protection UL 489 CSA C22.2 No. 5-02 short-circuit release 650 A Image #2

[4047621014524] Circuit breaker S3 system protection UL 489 CSA C22.2 No. 5-02 short-circuit release 650 A

  • EAN no.: 4047621014524
  • LM no.: 4047621014524
  • Supplier: SIEMENS A/S
Must login for adding to cart

Description

Type no.: 3RV2742-5JD10

Promotion code: 8008041910503

UNSPSC (v. 19.0501): 39121616

HS Code: 85362090

Circuit breaker size S3 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 50 A N-release 650 A screw terminal Circuit breaker SIRIUS 3RV2 For system protection according to UL 489/CSA C22.2 No. 5 for the short-circuit protection of systems and loads in plants configured in accordance with UL.
Thanks to their low heat loss, the compact and climate-resistant circuit breakers are optimized for use in load feeders, and also for IE3/IE4 motors, of course, and equally for the switching of direct current. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course.
Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch.
The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring.
The 3RV2 circuit breakers replace the well-proven 3RV1 series.
Simple, efficient and always up to date - SIRIUS modular system.

Specifications

Motor drive optional
FALSE
Integrated earth fault protection
FALSE
Suitable for DIN rail (top hat rail) mounting
FALSE
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
650 - 650
Switch off technique
Magnetic
With switched-off indicator
FALSE
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP)
IP20
Rated short-circuit breaking capacity lcu at 400 V, AC
100