circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole line protection TM240 ATAM In=160A overload protection Ir=112A. Image #0
circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole line protection TM240 ATAM In=160A overload protection Ir=112A. Image #1
circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole line protection TM240 ATAM In=160A overload protection Ir=112A. Image #2
circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole line protection TM240 ATAM In=160A overload protection Ir=112A. Image #0
circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole line protection TM240 ATAM In=160A overload protection Ir=112A. Image #1
circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole line protection TM240 ATAM In=160A overload protection Ir=112A. Image #2

circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole line protection TM240 ATAM In=160A overload protection Ir=112A.

  • EAN no.: 4042948831441
  • LM no.: 4042948831441
  • Supplier: SIEMENS A/S
Must login for adding to cart

Description

Type no.: 3VA1216-5EF32-0AA0

Promotion code: 8008043930275

UNSPSC (v. 19.0501): 39121601

HS Code: 85362090

circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=160A overload protection Ir=112A...160A short-circuit protection Ii=5...10 x In nut keeper kit 3VA1 molded-case circuit breaker for starter protection. As an important element of SENTRON protective components for industrial and infrastructure applications, the 3VA molded-case circuit breakers from Siemens provide effective plant, starter and motor protection thanks to reliable shutdown in the event of an overload or short circuit. The 3VA molded-case circuit breakers set new standards in flexibility and the variety of modular accessories available. Standardized accessories for several sizes across all series of the 3VA1 and 3VA2 molded-case circuit breakers. Key features of this version of the 3VA molded-case circuit breaker: 1. Compact design. 2. Available as version for starter circuit breaker to protect electrical motors from short circuits. 3. Available as 3-pole version. 4. Depending on the size: Rated operating current of 32 A to 200 A. 5. Breaking capacity of 55 kA to 70 kA at 415 V. 6. Fixed and plug-in installation possible. 7. The series has a thermo-magnetic trip unit 8. Modular and easy-to-fit internal accessories with wide range of functions. 9. Integrated accessories platform for all 3VA molded-case circuit breakers. www.siemens.de/3VA. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.

Specifications

Motor drive optional
TRUE
Overload release current setting
112 - 160
Integrated earth fault protection
FALSE
Suitable for DIN rail (top hat rail) mounting
TRUE
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
800 - 1600
With switched-off indicator
FALSE
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP)
IP40