Fixed low price
Færdiglavet boligtavle 2 x RCD, 2 x strøm, 1 x kombi, 8 x lys + transient
- EAN no.: 5708421009880
- LM no.: 7800440041
Must login for adding to cart
Description
Type no.: 44041
Promotion code: 80190999400
UNSPSC (v. 19.0501): 39121103
HS Code: 85371091
Suitable for homes larger than 150 m² that have, for example, a kitchen or utility room with many appliances, or a garage with a CE-rated outlet. The panel includes a rate-based circuit breaker and has two ground-fault circuit interrupters (GFCIs), which are evenly distributed across the two power circuits and eight lighting circuits. Additionally, a combination circuit breaker is installed, which has been tested to handle a 100% continuous load (used, for example, for an electric car charger). The transient protection safeguards the entire panel.
The distribution panel contains:
2 x RCD residual current circuit breakers 40A 4P 30mA (HPFI Type A)
2 x circuit breakers, 16 A, 3P+N, C, 4M, 6KA
1 x combination circuit breaker, 16 A, 3P+N, C, 4M, 6KA
8 x circuit breakers, 10 A, 1P+N, C, 1M, 6KA
1 x transient protection, Class 2, TT and TNS, 3P+N
1 group circuit breaker, 25A, 3P
1 VAERK group cover, 3 rows, white
The panel is manufactured in accordance with EN 61 439-3. If changes are made to the panel’s configuration, new calculations must be performed. Documentation for the panel is retained by LM in accordance with applicable legislation.
When contacting us regarding the panel, always provide the ID number, which is located on the inside of the cover.
The panel is designed for an operating voltage of 3x400/230V. Additional panel data can be found on the label inside the panel.
Important:
Be sure to retighten wire connections before commissioning, as transport and handling can loosen the terminals. Components should be tightened to between 2.0 Nm and 2.8 Nm, depending on the component’s maximum torque rating.
The panel must always be inspected and tested before commissioning as described in the KLS system.
If the panel includes surge protection (SPD), the feeder cable to the panel must be connected to it.
VAERK is Lemvigh-Müller’s own brand. With VAERK, you can expect professional quality, in-stock products, and competitive prices.
The distribution panel contains:
2 x RCD residual current circuit breakers 40A 4P 30mA (HPFI Type A)
2 x circuit breakers, 16 A, 3P+N, C, 4M, 6KA
1 x combination circuit breaker, 16 A, 3P+N, C, 4M, 6KA
8 x circuit breakers, 10 A, 1P+N, C, 1M, 6KA
1 x transient protection, Class 2, TT and TNS, 3P+N
1 group circuit breaker, 25A, 3P
1 VAERK group cover, 3 rows, white
The panel is manufactured in accordance with EN 61 439-3. If changes are made to the panel’s configuration, new calculations must be performed. Documentation for the panel is retained by LM in accordance with applicable legislation.
When contacting us regarding the panel, always provide the ID number, which is located on the inside of the cover.
The panel is designed for an operating voltage of 3x400/230V. Additional panel data can be found on the label inside the panel.
Important:
Be sure to retighten wire connections before commissioning, as transport and handling can loosen the terminals. Components should be tightened to between 2.0 Nm and 2.8 Nm, depending on the component’s maximum torque rating.
The panel must always be inspected and tested before commissioning as described in the KLS system.
If the panel includes surge protection (SPD), the feeder cable to the panel must be connected to it.
VAERK is Lemvigh-Müller’s own brand. With VAERK, you can expect professional quality, in-stock products, and competitive prices.