Fluke 114 EUR multimeter Image #0

Fluke 114 EUR multimeter

  • EAN no.: 0095969344791
  • LM no.: 7898100212
  • Supplier: FLUKE DANMARK A/S
Must login for adding to cart

Description

Type no: 2583552

Promotion code: 80160869051

UNSPSC (v. 19.0501): 41113630

HS Code: 90303100

Designed for easy one-hand operation, the Fluke 114 True RMS digital multimeter is the perfect troubleshooting tool for “go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. The LoZ function helps identify so-called “ghost voltage and prevent false readings.

Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10°C to + 50°C
Storage temperature -40°C to + 60°C
Battery type 9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001
V60.00 V / 0.01
V600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution
6.000 V / 0.001
V60.00 V / 0.01
V600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
Range/resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
1. All ac voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical & General Specifications
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g

Specifications

IR interface
FALSE
Max. voltage measuring range, AC
600
Max. resistance measuring range
40
Max. voltage measuring range, DC
600
Cable symmetry testing for two wire connections a-b-E
FALSE
Max. voltage measuring circuit category
600
Automatic circuit breaker
FALSE
Temperature measurement RTD
FALSE
Milliohm measurement with 4 wire technique (Kelvin connection)
FALSE
Cable length measurement
FALSE

Manuals and guides

Declaration of Conformity or Declaration of Performance