Fluke 62 MAX infrared thermometer4130474 Image #0

Fluke 62 MAX infrared thermometer4130474

  • EAN no.: 0095969620208
  • LM no.: 7898104467
  • Supplier: FLUKE DANMARK A/S
Login to add product to cart.

Description

Type no.: 5065894

Promotion code: 80160869055

UNSPSC (v. 19.0501): 41114408

HS Code: 90251900

Dust and water-resistant: IP54 rated for dust and water resistance.
Rugged: 3-meter (9.8-foot) drop tested.
Ergonomically designed: Completely redesigned for a more natural hand fit.
Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box.
Additional Features
Distance to spot: Precise laser technology makes for more accurate and repeatable measurements.
Dual lasers: The 62 MAX+ has dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots.
Large, backlit display: Large screen makes data easier to read, even in dark areas.
Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.
Alarm: Hi and Lo alarms for rapid display of measurements outside the limits.


Temperature Range
Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62 MAX+ -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX ±1.5 °C or ±1.5% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Fluke 62 MAX+ ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX <500 ms (95% of reading)
Fluke 62 MAX+ <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical Resolution
Fluke 62 MAX 10:1 (calculated at 90% energy)
Fluke 62 MAX+ 12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62 MAX+ ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
Fluke 62 MAX 10 hours with laser and backlight on
Fluke 62 MAX+ 8 hours with laser and backlight on
Physical Specifications
Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006
Standards and Agency Approval
Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
Power: Both the 62 MAX and 62 MAX+ are powered by a single, standard AA battery.

Specifications

Brand
Fluke
Indication
Digital
Infrared measurement
TRUE
Interface
FALSE
kg CO2 (Production)
21 (Proxy beregnet)
Measured value memory
FALSE
Measurement of differential temperature
TRUE
Measurement of material humidity
FALSE
Measurement of relative air humidity
FALSE
Measuring range
-30 - 500

Documents and Links