ICP DAS
ICPDAS PM-3033-MTCP Smart Power Meter 3-phase 1A/5A CT input 10 to 500VAC 50/60Hz -20 to 70°C PoE Modbus/TCP
- EAN no.: 5703431490963
- LM no.: 7886329937
Must login for adding to cart
Description
Type no: 49096
Promotion code: 80080211115
UNSPSC (v. 19.0501): 43222600
HS Code: 85176200
ICPDAS PM-3033-MTCP
Smart Power Meter, 3-phase, 1A/5A CT input, 10 to 500VAC, 50/60Hz, -20 to 70°C, PoE, Modbus/TCP
With this Smart Power Meter, which can be easily installed in new or existing systems, you can quickly read many different parameters via Modbus/TCP, e.g. kWh.
The accuracy is 0.5% at PF=1, so it is not approved for billing, but it can be used in many other situations, e.g. to monitor fans, reading power used for a given production, for dividing energy consumption and much more.
Current transformers are not included with this model, but standard /1A or /5A current transformers can be connected.
Models incl. current transformers can be supplied on request.
Following data can be collected via Modbus/TCP.
True RMS voltage (Vrms)
True RMS current (Irms)
Active Power (kW)
Active Energy (kWh)
Apparent Power(kVA)
Apparent Energy (kVAh)
Reactive Power (kVAR)
Reactive Energy (kVARh)
Power Factor (PF)
Frequency
Different ways to make the CT connection
3 phase, 4 wire, 3 Curret Transformers
3 pahse, 3 wire, 2 Curret Transformers
3 phase, 3 wire, 3 Curret Transformers
1 phase, 2 wire, 1 Curret Transformers
1 phase, 3 wire, 2 Curret Transformers
Accuracy 0,5% at PF=1
Measuring voltage = 10 til 500VAC
Measuring Frequency = 50 or 60Hz
Current Transformer (CT) 3 input 1A/5A (not included)
Mounting at DIN-rail
Power input 12 til 48 VDC or PoE
Temperature -20 til 70°C
Smart Power Meter, 3-phase, 1A/5A CT input, 10 to 500VAC, 50/60Hz, -20 to 70°C, PoE, Modbus/TCP
With this Smart Power Meter, which can be easily installed in new or existing systems, you can quickly read many different parameters via Modbus/TCP, e.g. kWh.
The accuracy is 0.5% at PF=1, so it is not approved for billing, but it can be used in many other situations, e.g. to monitor fans, reading power used for a given production, for dividing energy consumption and much more.
Current transformers are not included with this model, but standard /1A or /5A current transformers can be connected.
Models incl. current transformers can be supplied on request.
Following data can be collected via Modbus/TCP.
True RMS voltage (Vrms)
True RMS current (Irms)
Active Power (kW)
Active Energy (kWh)
Apparent Power(kVA)
Apparent Energy (kVAh)
Reactive Power (kVAR)
Reactive Energy (kVARh)
Power Factor (PF)
Frequency
Different ways to make the CT connection
3 phase, 4 wire, 3 Curret Transformers
3 pahse, 3 wire, 2 Curret Transformers
3 phase, 3 wire, 3 Curret Transformers
1 phase, 2 wire, 1 Curret Transformers
1 phase, 3 wire, 2 Curret Transformers
Accuracy 0,5% at PF=1
Measuring voltage = 10 til 500VAC
Measuring Frequency = 50 or 60Hz
Current Transformer (CT) 3 input 1A/5A (not included)
Mounting at DIN-rail
Power input 12 til 48 VDC or PoE
Temperature -20 til 70°C