Klinger LUGB Vortex meter (saturated steam) DN100 7.9t/h at 1mPa 4..20mA+Modbus RS485
- EAN no.: 5710147753640
- LM no.: 3789992341
- Supplier: Klinger Danmark A/S
Must login for adding to cart
Description
Type no.: 88200127
Promotion code: 80260101010
UNSPSC (v. 19.0501): 41112501
HS Code: 90262080
Klinger LUGB is a Compact Vortex Flowmeter in industrial design for measuring liquid, gas or steam.
The Vortex Meter acts as a gas and steam meter - with no change other than an adjustment of the transmitter gain - a setting that is usually made at the factory, but otherwise is simply a matter of moving a switch. The basic equation for the measurement principle does not include any 'media data', which is why you can wet calibrate all meters during manufacture and simply use a simple electronic adaptation to other media.
Same flowmeter can be used to Liquid-, Gas- and Steam
Dimensions from DN15 up to DN300
Can be delivered with integrated Pressure and Temperature sensor
Generel data
Type: Klinger LUGB
Dimensions: DN15 to DN300mm
Process Connections: Flange or Wafer
Wetted Parts: Stainless Steel (304 or 316)
Sensor type: Piezoceramic sensor
Accuracy: Liquid: ± 1% of Measured Value (Re ≥ 20000), Gas/steam: ± 1,5% of Measured value (Re ≥ 20000)
Power Supply: 24VDC (± 15%)
Output: 4 to 20mA max load 300 Ohm Pulse
Communication: RS485
Specification: DN100, DIN PN16 flange, 0.79-7.9t/h at 1Mpa, 4..20mA+Modbus RS485
The Vortex Meter acts as a gas and steam meter - with no change other than an adjustment of the transmitter gain - a setting that is usually made at the factory, but otherwise is simply a matter of moving a switch. The basic equation for the measurement principle does not include any 'media data', which is why you can wet calibrate all meters during manufacture and simply use a simple electronic adaptation to other media.
Same flowmeter can be used to Liquid-, Gas- and Steam
Dimensions from DN15 up to DN300
Can be delivered with integrated Pressure and Temperature sensor
Generel data
Type: Klinger LUGB
Dimensions: DN15 to DN300mm
Process Connections: Flange or Wafer
Wetted Parts: Stainless Steel (304 or 316)
Sensor type: Piezoceramic sensor
Accuracy: Liquid: ± 1% of Measured Value (Re ≥ 20000), Gas/steam: ± 1,5% of Measured value (Re ≥ 20000)
Power Supply: 24VDC (± 15%)
Output: 4 to 20mA max load 300 Ohm Pulse
Communication: RS485
Specification: DN100, DIN PN16 flange, 0.79-7.9t/h at 1Mpa, 4..20mA+Modbus RS485