Moxa
MOXA MGATE MB3170-T Modbus Gateway for TCP and RTU/ASCII 2x LAN RJ45 + 1x Serial RS-232 DB9 / RS-422/485 TB DIN rail Extended temp -40 to +75°C CE FCC UL IECEx ATEX Class 1 Devision 2 DNV
- EAN no.: 5703431431614
- LM no.: 7886329539
Must login for adding to cart
Description
Type no: 43161
Promotion code: 80080211410
UNSPSC (v. 19.0501): 46171621
HS Code: 85176200
Modbus TCP Client (Master) or Modbus TCP Server (Slave)
Modbus RTU/ASCII Master or Modbus RTU/ASCII Slave
2x RJ45 LAN
1x TB & DB9 Male Serial RS232/422/485
50 bps to 921.6 kbps
ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485 = 1k or 150k ohm
Terminator for RS-485 = 120 ohm
Input voltage 12 to 48 VDC
-40 to 75°C
DNV, ATEX, CE, FCC certified
The MGate MB3170 and MB3270 are 1 and 2-port Modbus gateways, respectively, that convert between Modbus TCP, ASCII, and RTU communications protocols. The gateways provide both serial-to-Ethernet communication and serial (master) to serial (slave) communications. In addition, the gateways support simultaneously connecting serial and Ethernet masters with serial Modbus devices. The MGate MB3170 and MB3270 Series gateways can be accessed by up to 32 TCP master/clients or connect to up to 32 TCP slave/servers. Routing through the serial ports can be controlled by IP address, TCP port number or ID mapping. A featured priority control function allows urgent commands to obtain an immediate response. All models are rugged, DIN-rail mountable, and offer optional built-in optical isolation for serial signals.
Easy to configure and with included diagnostic software, it’s easy to find and correct communication problems, on both TCP and Serial side.
Modbus RTU/ASCII Master or Modbus RTU/ASCII Slave
2x RJ45 LAN
1x TB & DB9 Male Serial RS232/422/485
50 bps to 921.6 kbps
ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485 = 1k or 150k ohm
Terminator for RS-485 = 120 ohm
Input voltage 12 to 48 VDC
-40 to 75°C
DNV, ATEX, CE, FCC certified
The MGate MB3170 and MB3270 are 1 and 2-port Modbus gateways, respectively, that convert between Modbus TCP, ASCII, and RTU communications protocols. The gateways provide both serial-to-Ethernet communication and serial (master) to serial (slave) communications. In addition, the gateways support simultaneously connecting serial and Ethernet masters with serial Modbus devices. The MGate MB3170 and MB3270 Series gateways can be accessed by up to 32 TCP master/clients or connect to up to 32 TCP slave/servers. Routing through the serial ports can be controlled by IP address, TCP port number or ID mapping. A featured priority control function allows urgent commands to obtain an immediate response. All models are rugged, DIN-rail mountable, and offer optional built-in optical isolation for serial signals.
Easy to configure and with included diagnostic software, it’s easy to find and correct communication problems, on both TCP and Serial side.