Resistance thermometer TR10-B Ex i PT100 Cl.A 4-wire terminal block -30...+300°C insertion length 200mm Ø6 G1/2B
- EAN no.: 5710147883835
- LM no.: 7889544913
- Supplier: WIKA ALEXANDER SE+CO. KB
Login to add product to cart.
Description
Type no.: 14427060
Promotion code: 80080620011
UNSPSC (v. 19.0501): 41111970
HS Code: 90251900
Short product description:
WIKA TR10-B is a threaded resistance thermometer for installation in a separate thermowell/protection tube. It is suitable for precise temperature measurement in machine building, plant and vessel construction, energy and power plant technology, chemical industry and food and beverage applications. The design has a replaceable measuring insert and PT100 sensor for service replacement.
Variants and options:
• Sensor: PT100, 4-wire, Cl.A according to EN 60751
• Output/connection: Terminal block without transmitter
• Terminal block variants are supplied without transmitter for direct wiring
• Ex i variant for intrinsically safe applications in zone 1 gas
• For installation in a separate thermowell/protection tube
Product specification from column N:
• Model: TR10-B
• Approval: ATEX/IECEx Ex i, zone 1 gas
• Sensor: PT100, 4-wire, Cl.A, EN 60751
• Temperature range for selected class: -30...+300°C
• Measuring range in web name: -30...+300°C
• Measuring insert: Ø6 mm, stainless steel 316TI / 1.4571
• Insertion length l1/A/U2: 200 mm
• Connection head: BSZ, aluminium, spherical with hinged cover
• Cable entry: M20x1.5 standard cable gland
• Output/connection: Terminal block without transmitter
• Neck tube: 12x2.5 mm. 1.4571. M24 x 1.5 - G 1/2 B. MH=150 mm (approx. 6 inch)
• Neck length MH: 150 mm
• Sealing: Copper
• Measuring insert length as spare l5: 375 mm
• Data sheet: TE 60.02
WIKA TR10-B is a threaded resistance thermometer for installation in a separate thermowell/protection tube. It is suitable for precise temperature measurement in machine building, plant and vessel construction, energy and power plant technology, chemical industry and food and beverage applications. The design has a replaceable measuring insert and PT100 sensor for service replacement.
Variants and options:
• Sensor: PT100, 4-wire, Cl.A according to EN 60751
• Output/connection: Terminal block without transmitter
• Terminal block variants are supplied without transmitter for direct wiring
• Ex i variant for intrinsically safe applications in zone 1 gas
• For installation in a separate thermowell/protection tube
Product specification from column N:
• Model: TR10-B
• Approval: ATEX/IECEx Ex i, zone 1 gas
• Sensor: PT100, 4-wire, Cl.A, EN 60751
• Temperature range for selected class: -30...+300°C
• Measuring range in web name: -30...+300°C
• Measuring insert: Ø6 mm, stainless steel 316TI / 1.4571
• Insertion length l1/A/U2: 200 mm
• Connection head: BSZ, aluminium, spherical with hinged cover
• Cable entry: M20x1.5 standard cable gland
• Output/connection: Terminal block without transmitter
• Neck tube: 12x2.5 mm. 1.4571. M24 x 1.5 - G 1/2 B. MH=150 mm (approx. 6 inch)
• Neck length MH: 150 mm
• Sealing: Copper
• Measuring insert length as spare l5: 375 mm
• Data sheet: TE 60.02