TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 12 V DC coil Image #0

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 12 V DC coil

  • EAN no.: 3389110354898
  • LM no.: 7522408361
  • Supplier: Schneider Electric
Must login for adding to cart

Description

Type no.: LC1D18JD

Promotion code: 80080470202

UNSPSC (v. 19.0501): 39121529

HS Code: 85364190

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 18A, 12 V DC coil. range: TeSys - product name: TeSys D - product or component type: contactor - device short name: LC1D - contactor application: motor control, resistive load - utilisation category: AC-1, AC-4, AC-3 - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - [Ie] rated operational current: 18 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 32 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power kW: 4 kW at 220...230 V AC 50/60 Hz AC-3, 4 kW at 400 V AC 50/60 Hz AC-4, 7.5 kW at 380...400 V AC 50/60 Hz AC-3, 10 kW at 660...690 V AC 50/60 Hz AC-3, 10 kW at 500 V AC 50/60 Hz AC-3, 9 kW at 415...440 V AC 50/60 Hz AC-3 - motor power hp: 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 1 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - [Ith] conventional free air thermal current: 32 A at <= 60 °C for power circuit, 10 A at <= 60 °C for signalling circuit - Irms rated making capacity: 300 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 - [Icw] rated short-time withstand current: 120 A 500 ms signalling circuit, 240 A <= 40 °C 1 s power circuit, 100 A 1 s signalling circuit, 140 A 100 ms signalling circuit, 84 A <= 40 °C 1 min power circuit, 145 A <= 40 °C 10 s power circuit, 40 A <= 40 °C 10 min power circuit - associated fuse rating: 35 A gG at <= 690 V coordination type 2 for power circuit, 50 A gG at <= 690 V coordination type 1 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1 - [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 600 V for power circuit certifications UL, 690 V for signalling circuit conforming to IEC 60947-1 - electrical durability: 1.65 Mcycles 18 A AC-3 at Ue <= 440 V, 1 Mcycles 32 A AC-1 at Ue <= 440 V - power dissipation per pole: 2.5 W AC-1, 0.8 W AC-3 - protective cover: with - mounting support: rail, plate - standards: EN 60947-5-1, CSA C22.2 No 14, UL 508, IEC 60947-5-1, EN 60947-4-1, IEC 60947-4-1 - product certifications: CCC, CSA, UL, GOST, RINA, BV, DNV, GL, LROS (Lloyds register of shipping) - connections - terminals: control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end, power circuit : screw clamp terminals 1 cable(s) 1...6 mm² - cable stiffness: flexible - with cable end, power circuit : screw clamp terminals 2 cable(s) 1.5...6 mm² - cable stiffness: flexible - without cable end, control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end, power circuit : screw clamp terminals 1 cable(s) 1.5...6 mm² - cable stiffness: flexible - without cable end, power circuit : screw clamp terminals 1 cable(s) 1.5...6 mm² - cable stiffness: solid - without cable end, power circuit : screw clamp terminals 2 cable(s) 1.5...6 mm² - cable stiffness: solid - without cable end, control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end, power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end, control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end - tightening torque: control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 - operating time: 53.55...72.45 ms closing, 16...24 ms opening - safety reliability level: B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 - mechanical durability: 30 Mcycles. Benefits: In addition to its new look, the TeSys D contactor offers you quick simple setup, while maintaining a compact size of 45 and 55mm (40 to 65A) as well as compliance with international standards.. From 40 to 65A versions are equiped with EverLink, this new patented terminal technology, assures a permanent tightening quality even in the event of conductor creep.... Applications: Industry, infrastructure, building, etc:, TeSys D contactors have been designed for perfect integration in control systems, They can be used to create motor starters for any type of application., Switching contactor or relay coils, Powering control and signalling equipment....

Specifications

Modular version
FALSE
Voltage type for actuating
DC
Type of electrical connection of main circuit
Screw connection
Rated operation current Ie at AC-4, 400 V
9
Rated operation power at AC-4, 400 V
4
Depth
95
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
3

Documents and Links

Environmental Product Declaration

MD22 Product data sheet