TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 400 V AC coil Image #0
Schneider Electric

TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 400 V AC coil

  • EAN no.: 3389110385366
  • LM no.: 7522413181
  • Supplier: Schneider Electric
Must login for adding to cart

Description

Type no.: LC2D09V7

Promotion code: 80080470202

UNSPSC (v. 19.0501): 39121529

HS Code: 85364900

TeSys D reversing contactor, 3p(3 NO), AC-3, <= 440 V 9A, 400 V AC coil. range: TeSys - product name: TeSys D - device short name: LC2D - contactor application: motor control, resistive load - utilisation category: AC-3, AC-1 - device presentation: preassembled with reversing power busbar - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - [Ie] rated operational current: 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power kW: 5.5 kW at 500 V AC 50/60 Hz, 5.5 kW at 660...690 V AC 50/60 Hz, 4 kW at 380...400 V AC 50/60 Hz, 4 kW at 415...440 V AC 50/60 Hz, 2.2 kW at 220...230 V AC 50/60 Hz - motor power hp: 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 25 A at <= 60 °C for power circuit - Irms rated making capacity: 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 - [Icw] rated short-time withstand current: 120 A 500 ms signalling circuit, 30 A <= 40 °C 10 min power circuit, 61 A <= 40 °C 1 min power circuit, 210 A <= 40 °C 1 s power circuit, 100 A 1 s signalling circuit, 105 A <= 40 °C 10 s power circuit, 140 A 100 ms signalling circuit - associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 20 A gG at <= 690 V coordination type 2 for power circuit, 25 A gG at <= 690 V coordination type 1 for power circuit - [Ui] rated insulation voltage: 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for power circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 - electrical durability: 0.6 Mcycles 25 A AC-1 at Ue <= 440 V, 2 Mcycles 9 A AC-3 at Ue <= 440 V - power dissipation per pole: 0.2 W AC-3, 1.56 W AC-1 - protective cover: with - interlocking type: mechanical - mounting support: rail, plate - standards: IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14, UL 508, EN 60947-4-1, EN 60947-5-1 - product certifications: CSA, UL, GL, BV, DNV, GOST, LROS (Lloyds register of shipping), RINA, CCC - connections - terminals: control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end, power circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end, control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end, power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end, power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end, power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end - tightening torque: power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm - operating time: 12...22 ms closing, 4...19 ms opening - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - mechanical durability: 15 Mcycles. Benefits: .. Applications: .. Benefits: In addition to its new look, the TeSys D contactor offers you quick simple setup, while maintaining a compact size of 45 and 55mm (40 to 65A) as well as compliance with international standards.. From 40 to 65A versions are equiped with EverLink, this new patented terminal technology, assures a permanent tightening quality even in the event of conductor creep.... Applications: Industry, infrastructure, building, etc:, TeSys D contactors have been designed for perfect integration in control systems, They can be used to create motor starters for any type of application., Switching contactor or relay coils, Powering control and signalling equipment....

Specifications

Rated operation power NEMA
3.73
Degree of protection (NEMA)
Other
Operating voltage AC 60 Hz
440 - 440
Operating voltage AC 50 Hz
440 - 440
Voltage type (operating voltage)
AC
Voltage type for actuating
AC
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP)
IP20
Depth
86
Number of auxiliary contacts as normally closed contact
1