Type no: TM3BCEIP
Promotion code: 80080493220
UNSPSC (v. 19.0501): 32151705
HS Code: 85176200
The TM3BCEIP bus coupler module is used to create distributed I/O islands,
managed by a master controller via the Ethernet communication network, and to
exchange data using the EtherNet/IP and Modbus/TCP protocols between the
controllers and the distributed I/O on the Ethernet network.
It is compatible with Modicon M221 (1) , M241, and M251 logic controllers and
Modicon M262 logic/motion controller.
(1) Compatible with Modicon M221 logic controllers in Q1 2020
Specific features:
-Embedded Web server
-Embedded cybersecurity (Achilles L1) and user access rights management via a Web server
-Two isolated RJ45 ports on the front of the module for communication over Ethernet (the second port can be connected to other devices in a daisy chain or ring topology)
-Ethernet half duplex/full duplex service, autonegotiation, and auto-MDIX supported
-10/100 Mbps data transfer rate (physical layer interface in RMII mode, with automatic cable detection supported)
Ethernet services:
- EtherNet/IP Adapter
- Modbus TCP/IP server
- EtherNet/IP protocol version: IPv4, limited use of IPv6 (only default @)
- RSTP ring topology supported
- Simple Network Management Protocol (SNMP)
- Devices Profile for Web Services (DPWS)
- FDR client
- DHCP client
- BOOTP client
- Address conflict detection
Configuration:
The TM3BCEIP bus coupler module connects to Modicon M241 and Modicon M251
logic controllers and Modicon M262 logic/motion controller according to the general
rules for the TM3 system: 7 local modules max. plus 7 remote or distributed modules.
managed by a master controller via the Ethernet communication network, and to
exchange data using the EtherNet/IP and Modbus/TCP protocols between the
controllers and the distributed I/O on the Ethernet network.
It is compatible with Modicon M221 (1) , M241, and M251 logic controllers and
Modicon M262 logic/motion controller.
(1) Compatible with Modicon M221 logic controllers in Q1 2020
Specific features:
-Embedded Web server
-Embedded cybersecurity (Achilles L1) and user access rights management via a Web server
-Two isolated RJ45 ports on the front of the module for communication over Ethernet (the second port can be connected to other devices in a daisy chain or ring topology)
-Ethernet half duplex/full duplex service, autonegotiation, and auto-MDIX supported
-10/100 Mbps data transfer rate (physical layer interface in RMII mode, with automatic cable detection supported)
Ethernet services:
- EtherNet/IP Adapter
- Modbus TCP/IP server
- EtherNet/IP protocol version: IPv4, limited use of IPv6 (only default @)
- RSTP ring topology supported
- Simple Network Management Protocol (SNMP)
- Devices Profile for Web Services (DPWS)
- FDR client
- DHCP client
- BOOTP client
- Address conflict detection
Configuration:
The TM3BCEIP bus coupler module connects to Modicon M241 and Modicon M251
logic controllers and Modicon M262 logic/motion controller according to the general
rules for the TM3 system: 7 local modules max. plus 7 remote or distributed modules.