Thermowell TW50-H Form 6 G1/2 male/fem 316TI U1=232 bore Ø9 sensor Ø8x250mm
- EAN no.: 5710147884474
- LM no.: 7889545556
- Supplier: WIKA ALEXANDER SE+CO. KB
Login to add product to cart.
Description
Type no.: 3909203
Promotion code: 80080620001
UNSPSC (v. 19.0501): 41112410
HS Code: 90259000
Short product description:
TW50-H is a solid-machined threaded thermowell/protection tube according to DIN 43772 Form 6. It separates the process from the temperature sensor or thermometer and protects measuring equipment, environment and personnel under high process loads. The sensor can be replaced without direct contact with the process medium.
Important selection information:
• Process connection: G 1/2 B male thread for screw-in mounting into the process
• Connection to sensor/thermometer: G 1/2 female thread
• U1 is the thermowell insertion length: 232 mm
• Overall thermowell length L = U1 + 28 mm = 260 mm
• Suitable sensor/thermometer stem length incl. thread: l1 = U1 + 18 mm = 250 mm
• The sensor thread must match the thermowell internal thread
• The sensor stem diameter must be smaller than the bore diameter (Ø9 mm)
Product specification:
• Model: TW50-H
• Form: 6
• Material: stainless steel 316TI
• Bore size: Ø9 mm
• Suitable sensor diameter: < Ø9 mm, typically Ø8 mm
• Data sheet: TW 95.50
TW50-H is a solid-machined threaded thermowell/protection tube according to DIN 43772 Form 6. It separates the process from the temperature sensor or thermometer and protects measuring equipment, environment and personnel under high process loads. The sensor can be replaced without direct contact with the process medium.
Important selection information:
• Process connection: G 1/2 B male thread for screw-in mounting into the process
• Connection to sensor/thermometer: G 1/2 female thread
• U1 is the thermowell insertion length: 232 mm
• Overall thermowell length L = U1 + 28 mm = 260 mm
• Suitable sensor/thermometer stem length incl. thread: l1 = U1 + 18 mm = 250 mm
• The sensor thread must match the thermowell internal thread
• The sensor stem diameter must be smaller than the bore diameter (Ø9 mm)
Product specification:
• Model: TW50-H
• Form: 6
• Material: stainless steel 316TI
• Bore size: Ø9 mm
• Suitable sensor diameter: < Ø9 mm, typically Ø8 mm
• Data sheet: TW 95.50