Fixed low price
TopAC 22kW Wall Charger EVPC02-22W - Powered By Shelly
- EAN no.: 3800238074906
- LM no.: 7811301182
- Supplier: Shelly Europe Ltd
Login to add product to cart.
Description
Type no.: 3800238074906
Promotion code: 80210777
UNSPSC (v. 19.0501): 39121800
HS Code: 85044060
TopAC 22kW Wall Charger (EVPC02-22W) is a wall-mounted charging station for permanent hardwired installation on a three-phase 400 V supply. It delivers up to 22 kW, has a fixed 5 metre Type 2 cable and a 3.5" colour screen showing status, energy use and any error codes on the unit itself. Charging current is set from 6 to 32 A in the Shelly Smart Control app.
Auto Balance watches the total household consumption and automatically reduces the charging current when other heavy loads are running, so the main fuse holds. The function requires a Shelly energy meter — Shelly EM Gen2, Pro or newer. On top of that come scheduled charging, so the car charges when electricity is cheapest, and limits on how many kWh and how long a single session may run.
Important when planning the job: the charger is hardwired and must be installed by an authorised electrician. It requires a three-phase 400 V TN system (TN-C or TN-S) and therefore cannot be used on a 230 V IT or TT system. This is worth checking in Norway in particular, where many homes still run an IT system.
Set up and controlled in the Shelly Smart Control app. The charger connects over Wi-Fi, Bluetooth or Ethernet (RJ45) and needs no hub. According to the product documentation it is compatible with Shelly Smart Control, Shelly Cloud and Home Assistant. As a Powered by Shelly product it is built with the Shelly X chip and developed in close collaboration with Shelly. All primary functions run 100 % locally: schedules and scenes live in the charger itself, so charging continues even when the internet is down.
Use cases
• Home charging without overloading the installation: Auto Balance turns the current down when the oven, heat pump and hob are all running, and back up afterwards.
• Overnight charging on price: scheduled charging starts and stops by itself, so the car charges in the cheap hours without anyone remembering to.
• Control over the individual session: set a limit on both kWh and duration, so a forgotten session does not run all night.
• Company parking: several chargers on one site, with consumption readable per unit.
• Rentals and shared parking: the display and energy data make it possible to follow what has been charged.
• Bluetooth gateway: the charger can act as a gateway for nearby Shelly BLU devices, so a carport sensor does not need a gateway of its own.
Installation, safety and technical
• Hardwired connection, three-phase 400 V AC, 50/60 Hz. Requires a TN-C or TN-S earthing system. To be installed by an authorised electrician.
• Built-in residual current protection: RCD type A (30 mA AC) plus 6 mA DC detection. The circuit must still be protected by a type A RCD in the panel.
• Charging current set from 6 to 32 A in the app — up to 22 kW at 32 A across three phases.
• Type 2 connector (EN 62196) on a fixed 5 metre TPU cable, 5G6.0 mm² + 1G2.5 mm². Rated for more than 10,000 mating cycles.
• Protections: over- and undervoltage, overcurrent, over-temperature, leakage current, short circuit, missing earth connection, relay fault and thermal monitoring of the plug. The charger runs a self-test before every session.
• Display and light: 3.5" colour screen with status, energy use and error codes, plus LED indication of charging status.
• Housing and materials: IP65 on the control box, protection class I, flame class UL94-V0. Operating temperature -25 to 45 °C.
• Connectivity: Wi-Fi 802.11 b/g/n (2.4 GHz), Bluetooth 5 and Ethernet over RJ45. No hub required.
• Certification: DEKRA CE, CB and RoHS. Complies with IEC 61851, IEC 62196 and EN 50620 / IEC 62893. Two-year warranty.
Auto Balance watches the total household consumption and automatically reduces the charging current when other heavy loads are running, so the main fuse holds. The function requires a Shelly energy meter — Shelly EM Gen2, Pro or newer. On top of that come scheduled charging, so the car charges when electricity is cheapest, and limits on how many kWh and how long a single session may run.
Important when planning the job: the charger is hardwired and must be installed by an authorised electrician. It requires a three-phase 400 V TN system (TN-C or TN-S) and therefore cannot be used on a 230 V IT or TT system. This is worth checking in Norway in particular, where many homes still run an IT system.
Set up and controlled in the Shelly Smart Control app. The charger connects over Wi-Fi, Bluetooth or Ethernet (RJ45) and needs no hub. According to the product documentation it is compatible with Shelly Smart Control, Shelly Cloud and Home Assistant. As a Powered by Shelly product it is built with the Shelly X chip and developed in close collaboration with Shelly. All primary functions run 100 % locally: schedules and scenes live in the charger itself, so charging continues even when the internet is down.
Use cases
• Home charging without overloading the installation: Auto Balance turns the current down when the oven, heat pump and hob are all running, and back up afterwards.
• Overnight charging on price: scheduled charging starts and stops by itself, so the car charges in the cheap hours without anyone remembering to.
• Control over the individual session: set a limit on both kWh and duration, so a forgotten session does not run all night.
• Company parking: several chargers on one site, with consumption readable per unit.
• Rentals and shared parking: the display and energy data make it possible to follow what has been charged.
• Bluetooth gateway: the charger can act as a gateway for nearby Shelly BLU devices, so a carport sensor does not need a gateway of its own.
Installation, safety and technical
• Hardwired connection, three-phase 400 V AC, 50/60 Hz. Requires a TN-C or TN-S earthing system. To be installed by an authorised electrician.
• Built-in residual current protection: RCD type A (30 mA AC) plus 6 mA DC detection. The circuit must still be protected by a type A RCD in the panel.
• Charging current set from 6 to 32 A in the app — up to 22 kW at 32 A across three phases.
• Type 2 connector (EN 62196) on a fixed 5 metre TPU cable, 5G6.0 mm² + 1G2.5 mm². Rated for more than 10,000 mating cycles.
• Protections: over- and undervoltage, overcurrent, over-temperature, leakage current, short circuit, missing earth connection, relay fault and thermal monitoring of the plug. The charger runs a self-test before every session.
• Display and light: 3.5" colour screen with status, energy use and error codes, plus LED indication of charging status.
• Housing and materials: IP65 on the control box, protection class I, flame class UL94-V0. Operating temperature -25 to 45 °C.
• Connectivity: Wi-Fi 802.11 b/g/n (2.4 GHz), Bluetooth 5 and Ethernet over RJ45. No hub required.
• Certification: DEKRA CE, CB and RoHS. Complies with IEC 61851, IEC 62196 and EN 50620 / IEC 62893. Two-year warranty.