Variable speed drive ATV630 - 315kW - 380...440V - IP21 Image #0

Variable speed drive ATV630 - 315kW - 380...440V - IP21

  • EAN no.: 3606485410807
  • LM no.: 7565723346
  • Supplier: Schneider Electric
Must login for adding to cart

Description

Type no: ATV630C31N4F

Promotion code: 80080485225

UNSPSC (v. 19.0501): 39121007

HS Code: 85044095

variable speed drive ATV630 - 315kW - 380...440V - IP21. Label: Altivar Process ATV600 - range of product: Altivar Process ATV600 - type of cooling: forced convection - supply frequency: 50...60 Hz - 5...5 % - network number of phases: 3 phases - [Us] rated supply voltage: 380...440 V - 15...10 % - motor power kW: 250 kW (heavy duty) ,315 kW (normal duty) - line current: 538 A at 400 V (normal duty) ,432 A at 400 V (heavy duty) ,453 A at 380 V (heavy duty) ,566 A at 380 V (normal duty) - prospective line Isc: 50 kA - apparent power: 299 kVA at 440 V (heavy duty) ,373 kVA at 440 V (normal duty) - product or component type: variable speed drive - continuous output current: 590 A at 2.5 kHz for normal duty ,477 A at 2.5 kHz for heavy duty - maximum transient current: 649 A during 60 s (normal duty) ,715.5 A during 60 s (heavy duty) - asynchronous motor control profile: constant torque standard,variable torque standard,optimized torque mode - synchronous motor control profile: permanent magnet motor,synchronous reluctance motor - output frequency: 0.0001-0.5 kHz - speed drive output frequency: 0.1-599 Hz - nominal switching frequency: 2.5 kHz - switching frequency: 2.5...8 kHz with derating factor ,2...8 kHz adjustable - safety function: STO (safe torque off) SIL 3 - product specific application: process and utilities - discrete input logic: 16 preset speeds - communication port protocol: Ethernet,Modbus serial,Modbus TCP - option card: communication module, Ethernet Powerlink , communication module, BACnet MS/TP ,slot A/slot B digital and analog I/O extension module ,slot A communication module, CANopen screw terminals ,slot A communication module, Modbus TCP/EtherNet/IP ,slot A communication module, Profibus DP V1 ,slot A communication module, CANopen SUB-D 9 ,slot A communication module, Ethernet IP/Modbus TCP/MD-Link ,slot A/slot B output relay extension module ,slot A communication module, Profinet ,slot A communication module, CANopen daisy chain RJ45 ,slot A communication module, DeviceNet - device short name: ATV630 - variant: standard version - product destination: asynchronous motors,synchronous motors - mounting mode: floor-standing - EMC filter: integrated conforming to EN/IEC 61800-3 category C3 - IP degree of protection: IP21 conforming to IEC 60529 ,IP21 conforming to IEC 61800-5-1 - Range Presentation:
Altivar Process is a Services Oriented Drive designed to reduce OPEX in Process & Utilities installations, thanks to embedded EcoStruxure Machine Advisor.
ATV600 is a range of ready-to-order drives and custom engineered drives focused on fluids management processing and energy saving.
Altivar Process is the first Services Oriented Drive with:
• Embedded Power measurement and Energy dashboard
• Embedded process monitoring and control
• Low Harmonics (THDi 48% at 80% load or THDi 5% with low harmonic offer)
• Stop and Go function to reduce energy consumption in standby mode
• Asset monitoring and protection
• Drift monitoring
• Easy maintenance (Dynamic QR-Code)
• Seamless integration with embedded Ethernet: o From device to process control with the Smart Process Object
o From data to insights with the embedded Web Server
Custom Engineered Drives:
Proven technical cooling and harmonics solutions
• Modular and compact design
• Easy grid integration
• Embedded Control (PLC, RTU, HMI)
• A full set of control options
• Fully load tested in a controlled laboratory environment
• Complies with your country’s industry standards
- Range Benefits:
Services Oriented Drives
This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and Total Cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
• Sustainable cost savings thanks to predictive condition-based maintenance
• Up to 20% downtime reduction without additional investment
Fluids Management Processing
• Embedded Pump curves embedded (easy to set 5 points curve)
• Anti-jam function prevents downtime
• Limits leakage by reducing pressure when demand is low
Energy Saving
• Optimizes energy consumption
• Accurate power measurement provides information for energy management
• Reduced energy consumption in standby mode
Real Time Intelligence
Web server and services via Ethernet
• Embedded web server interface based on the Ethernet network gives you process monitoring with your daily working tools
• Local and remote access to energy use and customized dashboards means your energy useage is visible anywhere, any time, on PC, tablet or smartphone.
Custom Engineered Drives
Schneider Electric’s expertise in design and application services delivers solution-specific designs dedicated to your process requirements for seamless plant integration.
• Minimize design and delivery risks
• Reduces the commissioning and adaptation time
Enhanced Drives Specifications
Compact and modular, suitable even in harsh environments, Altivar Process is perfect for upgrades, retrofits, or new installations.
• Withstand the harsh conditions of use, both from an electrical and environmental perspective
- Range Application Presentation: Altivar Process drives have been specifically designed for industrial processes, such as:
WWW: Pumping, suction, dosing, odour control, ventilation, aeration and sludge removal
O&G: Pumps (submersible, hydraulic, pipeline, reverse flow, water injection, kerosene)
MMM:Pumps
F&B: Pumps and drying fan

Specifications

Max. output frequency
500
Max. output at linear load at rated output voltage
315
Max. output at quadratic load at rated output voltage
315
Integrated breaking resistance
FALSE
Application in industrial area permitted
TRUE
Application in domestic- and commercial area permitted
TRUE
Supporting protocol for CAN
FALSE
Supporting protocol for KNX
FALSE
Supporting protocol for Modbus
TRUE
Supporting protocol for INTERBUS
FALSE