Fixed low price
Zaptec Go 2 - Asphalt Black
- EAN no.: 7090038510575
- LM no.: 7811301069
- Supplier: ZAPTEC DANMARK APS
Must login for adding to cart
Description
Type no.: 900-00120
Promotion code: 80190777
UNSPSC (v. 19.0501): 25175002
HS Code: 85371091
Zaptec Go 2 is a wall-mounted AC charging station in accordance with IEC 61851-1, EVSE Mode 3.
Dimensions (mm)
H: 239 x W: 178 x D: 73
Weight
1.6 kg
Installation circuit
An external circuit breaker and RCD protection are required in accordance with local regulations.
Installation network, voltage
TN, IT and TT
230 VAC ± 10%
400 VAC ± 10%
Maximum current and charging output
22 kW at 32 A / 3-phase (TN network)
7.4 kW at 32 A / 1-phase (IT network)
7.4 kW at 32 A / 1-phase (TN network)
Charging socket
IEC 62196-2 Type 2 female
Electronic lock, can be permanently locked by the user
Integrated residual current protection
RDC-DD (6 mA DC) in accordance with IEC 62955
Electronic, automatic reset when a Type 2 cable is reinserted
Energy metering
Integrated energy meter
Certified MID Class B
EN 50470-1: 2006,
EN 50470-3: 2006
Communication interface and cloud connectivity/network
4G LTE Cat 1
Wi-Fi 2.4 GHz, 802.11 b/g/n
HMI, identification and configuration
Bluetooth Low Energy (BLE 4.2)
RFID reader ISO/IEC 14443 Type A 13.56 MHz (MIFARE Classic, MIFARE DESFire)
Backlit IPS LCD screen and RGBW LED ring for device status
2.5 W power consumption in standby
ISO 15118 hardware support
Standards and approvals
CE compliant with Radio Equipment Directive 2014/53/EU,
RoHS Directive 2011/65/EU, EN IEC 61851-1, IEC 61439-7 and IEC 62955
Temperature range
–30°C to +50°C
Degree of protection
IP54, indoor and outdoor use
IK10 impact protection
UL94 5VB flammability rating
UV-resistant
Electrical protection
Protection class I (4 kV AC and 6 kV impulse, insulation)
Overvoltage category III (4 kV)
Available software interfaces
Zaptec app
Third-party integration options (API, webhooks)
OCPP 1.6J (cloud) or OCPP Native (direct)
See https://zaptec.com/ocpp
Dimensions (mm)
H: 239 x W: 178 x D: 73
Weight
1.6 kg
Installation circuit
An external circuit breaker and RCD protection are required in accordance with local regulations.
Installation network, voltage
TN, IT and TT
230 VAC ± 10%
400 VAC ± 10%
Maximum current and charging output
22 kW at 32 A / 3-phase (TN network)
7.4 kW at 32 A / 1-phase (IT network)
7.4 kW at 32 A / 1-phase (TN network)
Charging socket
IEC 62196-2 Type 2 female
Electronic lock, can be permanently locked by the user
Integrated residual current protection
RDC-DD (6 mA DC) in accordance with IEC 62955
Electronic, automatic reset when a Type 2 cable is reinserted
Energy metering
Integrated energy meter
Certified MID Class B
EN 50470-1: 2006,
EN 50470-3: 2006
Communication interface and cloud connectivity/network
4G LTE Cat 1
Wi-Fi 2.4 GHz, 802.11 b/g/n
HMI, identification and configuration
Bluetooth Low Energy (BLE 4.2)
RFID reader ISO/IEC 14443 Type A 13.56 MHz (MIFARE Classic, MIFARE DESFire)
Backlit IPS LCD screen and RGBW LED ring for device status
2.5 W power consumption in standby
ISO 15118 hardware support
Standards and approvals
CE compliant with Radio Equipment Directive 2014/53/EU,
RoHS Directive 2011/65/EU, EN IEC 61851-1, IEC 61439-7 and IEC 62955
Temperature range
–30°C to +50°C
Degree of protection
IP54, indoor and outdoor use
IK10 impact protection
UL94 5VB flammability rating
UV-resistant
Electrical protection
Protection class I (4 kV AC and 6 kV impulse, insulation)
Overvoltage category III (4 kV)
Available software interfaces
Zaptec app
Third-party integration options (API, webhooks)
OCPP 1.6J (cloud) or OCPP Native (direct)
See https://zaptec.com/ocpp