Schneider Electric

Zelio control relay for current detection 0,15..15A 2C/O 8A 400VAC

  • EAN no.: 3606480792311
  • LM no.: 7523007198
  • Supplier: Schneider Electric
Login to add product to cart.

Description

Type no.: RM35JA32MT

Promotion code: 80080463215

UNSPSC (v. 19.0501): 39122331

HS Code: 85364190

The Zelio RM35 control relay range brings to market 2 new key improvements.
- The backlight LED dials for adjustment makes it easy to use in any condition, even in dusty or poorly lit enviroments.
- The built-in testbutton simplifies commissioning and troubleshooting by a push of a button.

RM35JA32MT is a control relay for current measurement.
The measurement is done through the M and E1/E2/E3 terminals which offers 3 measuring ranges:
M and E1 = 0,15-1,5 A
M and E2 = 0,5-5 A
M and E3 = 1,5-15 A
The control relay is supplied by 400 VAC and made for 3-phase applications.

The relay has 4 illuminated dials for setting up the function of the relay.
On the top dial, you select the type of measurement that you want (overcurrent, undercurrent or a both at the same time).
You can also chose if the relay should remember the last measured value in case of a power cut (memory).
On the next dial, the measuring limit can be adjusted between 10 and 100% of the selected range.
The third dial set the hystereses which can be between 5 and 50%.
The bottom dial set the off-delay on the output which can be between 0,1 and 30 seconds.

The LED's on the front shows the status of the contacts.
The testbutton force the output when the timer is powered on.

Specifications

Brand
Schneider Electric
Contains function DC-voltage overcurrent
TRUE
Contains function DC-voltage under current
TRUE
Current measuring range
0.15 - 15
Depth
73
External current transformer
FALSE
Function DC-current hysteresis
TRUE
Height
90
kg CO2 (Production)
9,26 (Leverandørdata)
Max. permitted delay-on energization time
0.3