ABB KNX Busch-Presence detector Corridor premium 6131/51-183-500

ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
2CKA006132A0414
7826108231
-
Discount code:
UNSPSC Code:
Customs code:
80080822067
39121107
85365080
ABB KNX Busch-Presence detector Corridor premium Detection range: rectangular. For mounting height of 3 m: frontal toward the detector at a max. of 20 m x 3 m (at a max. of 10 m x 3 m per side). Crosswise toward the detector at a max. of 30 m x 3 m (max. of 15 m x 3m per side). With integrated KNX bus coupler. Mounting height 27 mm. With 4 channels. For dimming/brightness of the rules to a defined value in a designated collection area. HVAC function for controlling heating and/or cooling systems and ventilation systems in the designated collection area. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light controller with up to two independent channels. Constant light controller with max. 2 outputs for dimming daylight control/rules of two rooflights in the room. Integrated object room temperature controller. 10 freely programmable IR channels (blue and/or white) Incl. 5 logic channels (logic gates, gates, delay and staircase lighting) Evaluation via internal brightness sensor. Weighting of up to 2 external brightness values ​​and the internal brightness sensor possible. The programming button can be activated with the IR transmitter 6010-25 (-500). Ceiling mounting on suspended ceilings with spring clamps, on solid ceilings in surface-mounting boxes 6131/39-xxx(-500) or on VDE flush-mounted boxes with intermediate ring for VDE flush-mounted boxes 6131/38-xxx(-500). Suitable for false ceilings with a board thickness from 9 to 25 mm. Hole size: Ø 68 mm. Cannot be installed in British Standard or VDE flushmounted box. Recommendation: Installation housing from Kaiser HaloX-O (Art.no. 1290-40) with corresponding cover plates (1290-47 or 1290-85 for fair faced concrete) or IBTronic H120-68 from Spelsberg. Connections: KNX-line: Bus connection terminal Protection class (Device): IP 20 Temperature range (Device): -5 °C to 45 °C Brightness limit value: 1 Lux - 1000 Lux Dimensions: (L x W x D): 91 mm x 91 mm x 49 mm Mounting depth: 22 mm Mounting height: 2 m - 4 m For software and description please check the current Online-Catalogue. HVAC = Heating/ ventilation/air-conditioning
Mounting methodSurface mounted (plaster)
ColourAluminium
ModelPresence detector
Surface protectionLacquered
Creep-under protectionYes
Number of channels4
Staircase monitoringYes
Material qualityThermoplastic
Max. transmission range frontally10
Max. transmission range sideways15
Bus system KNXYes
Bus system radio frequentNo
Bus system PowernetNo
Bus connection includedYes
MaterialPlastic
Bus system LONNo
Substation inputYes
RAL-number (similar)9006
Teach-function for response value luminosityYes
Operation mode switchNo
TransparentNo
Animal zoneNo
Surface finishingMatt
Min. switch-on time10
Max. duty cycle1092
Response value luminosity adjustableYes
Switch-off delay self-learningNo
Optimum mounting height3
Bus system KNX radioNo
Radio frequent bidirectionalNo
Min. depth of built-in installation box0
;