Circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=100A

SIEMENS A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
3VA2110-7MN36-0AA0
7822416613
-
Discount code:
UNSPSC Code:
Customs code:
8008043930274
39121615
85362090
Circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=100A overload protection Ir=40A...100A short-Circuit protection Isd=3...15 x Ir, Ii=15 x In clamp connection. Only mountable on DIN-rail by item 7822348244
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu100.0
Number of poles3
Overload release current setting40 - 100
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690
Degree of protection (IP)IP40
Position of connection for main current circuitFront side
Motor drive integratedNo
Type of electrical connection of main circuitFrame clamp
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz110.0
Adjustment range short-term delayed short-circuit release300 - 1500
Adjustment range undelayed short-circuit release1500 - 1500
Suitable for DIN rail (top hat rail) mountingYes
Integrated earth fault protectionNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
;