Doepke Residual current circuit-breakers, four-pole, 125 A, 0,30 A, Type B SK, N left
VANPEE A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
09176998
8822700205
-
Discount code:
UNSPSC Code:
Customs code:
80080075
39121614
85364900
Residual current circuit-breakers, four-pole, 125 A, 0,30 A, Type B SK, N left
Features:
high immunity against transient leakage and residual currents thanks to slow tripping response, meets the requirements of design regulations VDE 0664-10, VDE 0664-40, ÖVE/ÖNORM E 8601, AC/DC sensitive for residual currents with frequencies and mixed frequencies of 0 Hz (smooth direct current) up to 100 kHz, electromagnetic compatibility in accordance with VDE 0664-30 and VDE 0839-6-2 (interference resistance for industrial applications), high availability even of voltage-independent detection of smooth DC residual current and AC residual current with frequencies ≠ 50/60 Hz thanks to full functional compatibility with mains voltages from at least 50 V AC on any two active conductors, mains-voltage-independent tripping when type A residual currents occur, compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminal s for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductors with standard design left, for two-terminal -pair devices type A/AC/F up to 125 A and type B/B+ up to 80 A; N-right available at no extra charge.
Mounting method:
quick fastening to mounting rail, any installation position, supply preferably from above
Applications:
Commercial and industrial installations with TT, TN-S and TN-C-S systems, where power electronics equipment is used without galvanic isolation from the mains, e.g. frequency convertikalers, switching power supplies, high-frequency convertikalers, photovoltaic installations and UPS equipment with frequency convertikalers without transformers.
None