Fluke 772 procestangmeter til ma
FLUKE DANMARK A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
3362352
7898100555
-
Discount code:
UNSPSC Code:
Customs code:
80160869054
41113637
90303310
Fluke 772 milliamp clamp meter saves time & money by measuring output signals without breaking the loop or bringing down the system, and adds loop power.
Includes:
Four AA alkaline batteries (installed)
Soft carrying case
TL75 test leads
AC 72 detachable clip
TL 940 mini hook test leads
Instruction sheet
Hanging tool with hook and loop strap
Specifications
Diameter of measurable conductor 0.177” or 4.5 mm max
Operating temperature -10 to 50ºC
Storage temperature -25 to 60ºC
Operating humidity < 90% @ <30ºC, < 75% @ 30 to 55ºC
Operating altitude 0 to 2000 m
IP rating IP 40
Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight 410 g, (14.4 oz)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature coefficient 0.01% ºC
(< 18ºC or > 28ºC)
Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty Three years for electronics
One year for cable and clamp assembly
Functional Specifications
mA measurement
(measured by clamp) Resolution / range 0 to 20.99 mA
Accuracy 0.2% + 2 counts
Resolution / range 21.0mA to 100.0 mA
Accuracy 1% + 5 counts
mA measurement (measured in series with test jacks) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA source (maximum mA drive: 24 mA into 1,000 ohms) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA simulate (maximum voltage 50 V dc) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
None