Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

ICPDAS PM-3033-CPS, Smart Power Meter, 3-phase, 1A/5A CT input, 10 to 500VAC, 50/60Hz, -20 to 70°C, CANopen

ICP DAS
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
49942
7886329940
-
Discount code:
UNSPSC Code:
Customs code:
80080211115
43222600
85176200
ICPDAS PM-3033-CPS Smart Power Meter, 3-phase, 1A/5A CT input, 10 to 500VAC, 50/60Hz, -20 to 70°C, CANopen With this Smart Power Meter, which can be easily installed in new or existing systems, you can quickly read many different parameters via CANopen, e.g. kWh. The accuracy is 0.5% at PF=1, so it is not approved for billing, but it can be used in many other situations, e.g. to monitor fans, reading power used for a given production, for dividing energy consumption and much more. Current transformers are not included with this model, but standard /1A or /5A current transformers can be connected. Models incl. current transformers can be supplied on request. Following data can be collected via CANopen. True RMS voltage (Vrms) True RMS current (Irms) Active Power (kW) Active Energy (kWh) Apparent Power(kVA) Apparent Energy (kVAh) Reactive Power (kVAR) Reactive Energy (kVARh) Power Factor (PF) Frequency Different ways to make the CT connection 3 phase, 4 wire, 3 Curret Transformers 3 pahse, 3 wire, 2 Curret Transformers 3 phase, 3 wire, 3 Curret Transformers 1 phase, 2 wire, 1 Curret Transformers 1 phase, 3 wire, 2 Curret Transformers Accuracy 0,5% at PF=1 Measuring voltage = 10 til 500VAC Measuring Frequency = 50 or 60Hz Current Transformer (CT) 3 input 1A/5A (not included) Mounting at DIN-rail Power input 12 til 48 VDC Temperature -20 til 70°C

None

;