ICPDAS PM-3033, Smart Power Meter, 3-phase, 1A/5A CT input, 10 to 500VAC, 50/60Hz, -20 to 70°C, Modbus/RTU

ICP DAS
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
49095
7886329924
-
Discount code:
UNSPSC Code:
Customs code:
80080211115
43222600
85176200
ICPDAS PM-3033 Smart Power Meter, 3-phase, 1A/5A CT input, 10 to 500VAC, 50/60Hz, -20 to 70°C, Modbus/RTU With this Smart Power Meter, which can be easily installed in new or existing systems, you can quickly read many different parameters via Modbus/RTU, e.g. kWh. The accuracy is 0.5% at PF=1, so it is not approved for billing, but it can be used in many other situations, e.g. to monitor fans, reading power used for a given production, for dividing energy consumption and much more. Current transformers are not included with this model, but standard /1A or /5A current transformers can be connected. Models incl. current transformers can be supplied on request. Following data can be collected via Modbus/RTU. True RMS voltage (Vrms) True RMS current (Irms) Active Power (kW) Active Energy (kWh) Apparent Power(kVA) Apparent Energy (kVAh) Reactive Power (kVAR) Reactive Energy (kVARh) Power Factor (PF) Frequency Different ways to make the CT connection 3 phase, 4 wire, 3 Curret Transformers 3 pahse, 3 wire, 2 Curret Transformers 3 phase, 3 wire, 3 Curret Transformers 1 phase, 2 wire, 1 Curret Transformers 1 phase, 3 wire, 2 Curret Transformers Accuracy 0,5% at PF=1 Measuring voltage = 10 til 500VAC Measuring Frequency = 50 or 60Hz Current Transformer (CT) 3 input 1A/5A (not included) Mounting at DIN-rail Power input 12 til 48 VDC Temperature -20 til 70°C

None

;