Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

KNX CO2-Sensor basis

Wexøe
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
KNX AQS-UP-BASIC-HVID
7926007012
-
Discount code:
UNSPSC Code:
Customs code:
80010975004
39121800
90321089
The Air Quality Sensor KNX AQS-UP basic measures the CO2 concentration in the room. The sensor can receive an external CO2 value via the bus and process it with the own data to an overall value (mixed value, e. g. room average). The KNX AQS-UP basic provides four switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked by AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects. An integrated PI controllers allows to control of ventoation depending on CO2 concentration. Functions and Operation: Measurement of CO2 concentration of the air Mixed value from own measured value and external value (proportions can be set in percentage) PI controller to ventoation depending on CO2 concentration: dehumidification/humidification (one step) or dehumidification (one or two step) 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects) 8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the tom of communication objects) may be used as inputs to the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits 2 actuating variable comparators to output of minimum, maximum or avarage values Configuration is accomplished by means of the KNX software ETS Technical Data: Housing Plastic material (partly lacquered) Colours White glossy (similar to RAL 9016 Troffic White) Aluminium matt Anthracite matt Stainless steel Special colours on request Mounting In-wall (in socket Ø 60 mm, 42 mm deep) Protection category IP 20 Dimensions Housing approx. 55 × 55 (W × H, mm), mounting depth approx. 15 mm, base plate approx. 71 × 71 (W × H, mm) Total weight approx. 72 g Ambient temperature Operation -10 +50°C, storage -20 +60°C Ambient air humidity max. 95% RH, avoid bedewing Operating voltage KNX bus voltage Bus current max. 10 mA Data output KNX +/- bus terminal plug Communication objects 133 Measurement range CO2 0 2000 ppm

None

;