Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

Metrel MI3152 + EVSE-200

Elma Instruments
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
6398916554
6398916554
-
Discount code:
UNSPSC Code:
Customs code:
8016086901013
41113624
90303100
With this set consisting of the Metrel MI3152 Eurotest XC and the Elma EVSE-200, testing, verifying and documenting the installation of the charging socket and the charging socket's residual current protection has never been easier: Connect the MI3152 to the EVSE-200 with test leads, insert the EVSE-200 into the charging socket, and verify that the installation can now be done as on any other outlet. Remember that some chargers must be released via app or chip. Some charging sockets have built-in residual current protection, while others have left this up to the installer. In order to test the residual current protection correctly, it is necessary to know what type of residual current protection the charging plug is equipped with. • If the charging plug has a built-in RCD type A or B, we recommend an RCD test on the charging plug via the EVSE-200. • If the charging plug has built-in RDC-DD 6 mA DC protection, we recommend that this is tested on the charging plug via EVSE-200, while the front RCD is tested in the board. • If the charger does not have built-in residual current protection, an RCD test is carried out in the panel. Regardless of the type of residual current protection, Metrel AutoSequence is a powerful tool for proper RCD testing. After testing, the MI3152's unique memory structure and documentation software come into play. In the installation tester's built-in memory structure, measurement results are easily saved and named, for example case number or customer address. Subsequently, transfer measurements to Metrel ES Manager, and the report is printed or saved as .pdf with a single click. When using Metrel's aMESM android app, measurement results are transferred via bluetooth to the phone, and the report can be forwarded by email or conveniently saved as a .pdf. Then the documentation is under control!
IndicationGraphic
Low resistance measurementNo
Earthing measurementYes
InterfaceYes
Isolation resistance measurementYes
Over voltage protector testingYes
Loop resistance/impedance measurementYes
Mains internal resistance measurementYes
RCD/FI testingYes
Curve shape at RCD/FI testingFor earth leakage switch type A, F and type B, B+
Field rotation testYes
Selective grounding measurementYes
Earth loop measurementYes
Specific grounding measurementNo
Printer connectionNo
Limit value indicationYes
RCD/FI testing with rising residual currentYes
RCD/FI analysis functionYes
Detection short-circuit current/over current protectionYes
Remote control for testing deviceNo
Loop measurement without RCD/FI releaseYes
Resistances of isolating floors and wallsNo
Printer integratedNo
Isolation resistance measurement with ramp functionYes
Low resistance measurement with ramp functionNo
PRCD testing type S, type KYes
Testing of IMDs and RCMsNo
Measuring of leakage currents with adapterYes
Testing of charging devices E-Mobility, simulation of vehicle statusYes
Structured measured value memoryYes
;