Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

Mikrocable Viper 48XG657A1 Ø5,7MM T4000

Hexatronic
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
TOL4019028/48AH
7884128994
-
Discount code:
UNSPSC Code:
Customs code:
80120325010
39131715
39173200
Optical fiber Viper fiber 48F Drum size meter 0,8x0,58x0,8 4000m/drum Bøjningsradius : 75mm Tensile Force installation (N) : 1200 Crush (N/100mm) : 2000 Vægt : 28kg/km Product Color Black sheath Color Code S12 Temperature, Operation [°C] -45 to +70 Temperature, Storage [°C] -45 to +70 Temperature, Installation [°C] -15 to +50 Water Blocking Length water blocking according to IEC 60794-1-2-F5C Fiber Type G657A1 Attenuation @Wavelength [nm] 1310/1383/1550 Typical Attenuation [dB/km] 0.32/0.32/0.18 Average Attenuation [dB/km] 0.33/0.33/0.21 Maximum Attenuation [dB/km] 0.36/0.36/0.23 Conformance Length water blocking according to IEC 60794-1-2-F5C. Mechanical and environmental test in accordance with IEC 60794-5-10 Fiber parameters and tests according to the IEC series 60793-2 and 60793-1 Marking Example of sheath marking, 1 time/meter: “HEXATRONIC A35 Viper yymmddhh TOL4019028/432AH GNHL-U-CDGNRV 432/T12 G657A1 S12 xxxxx m” where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking Installation Notes Typical installation performance: • Ducts ID 8-10 mm, cable OD ≤6.7 mm: 2000 m • Ducts ID 12 mm, cable OD ≤8.0 mm: 2000 m • Ducts ID 15-16 mm, cable OD <11 mm: 2000 m, cable OD 11-12 mm: 1500 m Installation performance verified on Hexatronic test track, according to IEC 60794. Installation performance is affected by the installed path, environmental conditions, installation equipment etc and actual performance may therefore deviate from the above specified values. If the cable is installed by blowing the temperature shall be -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit.

None

;