Modbus Serial TM3BCCO Line bus coupler module for communication between Master (PLC) and Slaves For M221, M241, M251 and M262 PLC
Schneider Electric
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
TM3BCSL
7586060952
-
Discount code:
UNSPSC Code:
Customs code:
80080493094
39122214
85176200
Presentation:
The Modbus Serial Line meets the needs of master/slave architectures, and consists
of a master station and slave stations. Only the master station can initiate the
exchange (direct communication between slave stations is not possible).
Two exchange methods are possible:
b Question/reply, questions from the master are addressed to a specific slave.
The master waits for the reply to be returned by the slave polled.
b Distribution, the master distributes a message to all the slave stations on the bus.
These stations execute the instruction without sending a reply.
The TM3BCSL bus coupler module is designed to enable communication between
controllers (Master in the architecture) and numerous devices (Slaves) such as
HMIs, printers, energy meters, variable speed drives, motor starters, and remote I/O,
according to Modbus RS485 communication protocol.
TM3BCSL is compatible with Modicon M221, Modicon M241 and Modicon M251
logic controllers, Modicon M262 logic/motion controllers.
Configuration
The TM3BCSLbus coupler module connects to Modicon M221, Modicon M241 and
Modicon M251 logic controllers, and Modicon M262 logic/motion controllers according
to the general rules for the TM3 system: 7 local modules max. plus 7 remote or
distributed modules.
Format:
W x H x D: 27 x 96.5 x 70 mm (0.93 x 3.54 x 3.79 in.)
Mounting:
- The TM3BCSL bus coupler module is mounted on a symmetrical DIN rail.
- For plate or panel mounting, use the TMAM2 kit
None