Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

MS132-0.4 Manual Motor Starter Trip class 10, 0.25 - 0.4A

ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
1SAM350000R1003
7822411948
-
Discount code:
UNSPSC Code:
Customs code:
80080808011
39121616
85362010
MS132-0.4 manual motor starter is a compact 45 mm width devices with a rated operational current of Ie = 0.40 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
Width45
Height90
Depth86.75
Rated operation power at AC-3, 400 V0.09
With integrated auxiliary switchNo
Rated permanent current Iu0.4
With integrated under voltage releaseNo
Number of poles3
Rated operating voltage250 - 690
Overload release current setting0.25 - 0.4
Degree of protection (IP)IP20
With thermal protectionYes
Type of electrical connection of main circuitScrew connection
Type of control elementTurn button
Switch off techniqueThermomagnetic
Rated short-circuit breaking capacity lcu at 400 V, AC100
Adjustment range undelayed short-circuit release5 - 5
Phase failure sensitiveYes
Device constructionComplete device in housing
;