MS132-12T Circuit-breaker for primary transformer protection,Trip Class 10
ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
1SAM340000R1012
7822413263
-
Discount code:
UNSPSC Code:
Customs code:
80080808011
39121616
85362010
The circuit breaker for transformer protection MS132-12T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 12 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
Number of auxiliary contacts as normally open contact | 0 |
---|---|
Number of auxiliary contacts as normally closed contact | 0 |
Rated permanent current Iu | 12 |
Number of poles | 3 |
Overload release current setting | 8 - 12 |
Number of auxiliary contacts as change-over contact | 0 |
Rated voltage | 690 - 690 |
Degree of protection (IP) | IP20 |
Position of connection for main current circuit | Front side |
Motor drive integrated | No |
Type of electrical connection of main circuit | Screw connection |
Type of control element | Turn button |
With switched-off indicator | Yes |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | 100 |
Adjustment range undelayed short-circuit release | 240 - 240 |
Suitable for DIN rail (top hat rail) mounting | Yes |
Integrated earth fault protection | No |
Motor drive optional | No |
With under voltage release | No |
Device construction | Complete device in housing |
DIN rail (top hat rail) mounting optional | Yes |
Complete device with protection unit | Yes |