Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

MV installation cable PEX-S-AL 3X150/25 12KV red

Reka Cables
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
1187707 T500
5731100151
-
Discount code:
UNSPSC Code:
Customs code:
80190777
26121629
85446090
CONSTRUCTIONConductor: Solid 120° sector-shaped aluminium conductors (IEC 60228 class 1).Conductor screen: Semi-conducting cross-linked polyethylene with nominal thicknessof 0,5 mm.Insulation: Extruded cross-linked polyethylene (XLPE) having nominal thickness of 3,4 mm.Insulation screen: Semi-conducting XLPE with nominal thickness of 0,8 mm. Insulation screen isstrippable.Conductor screen, insulation and insulation screen are all extruded in thesame operation by triple-extrusion. Phase number identification is printed on eachinsulated conductor.Assebly: Insulated phase conductors laid-up together with plastic tapes between theconductors. A lapped layer of semiconducting tape over conductor assembly as abinder.Metallic screen: Cu-screen made of helically applied copper wires with a counter helix copper tape.Lapped plastic tapes wrapped over copper screen.Sheath: Red weather resistant polyethylene (PEMD) sheath.Temperature limits: Max. conductor temperature 90 °CMax. short circuit temperature 250 °C (duration not exceeding 5 sec.)Min. temperature during handling and installation - 20 °CMin. temperature during transport - 40 °CApplications: Cable is intended for fixed installations indoors and outdoors, on cable ladders, inconduits and cable ducts. Not for submarine applications. This article is approved for use in installations that are 'Svanemærket'
Dimension (mm²)150/25
Antal ledere3
;