Orion3-4-K1C-050-B - Active unit
ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
2TLA022306R0000
7824710773
-
Discount code:
UNSPSC Code:
Customs code:
80080823
39122205
90329000
Orion3 Base Light Grids, Active unit, 2 beams, Protected height=500mm, Range=0.5-8m, Type 4.
Voltage type | AC |
---|---|
Cascadable | No |
Suitable for safety functions | Yes |
Ambient temperature | 0 - 0 |
Number of semiconductor outputs with signalling function | 0 |
Number of contact energized outputs with signalling function | 0 |
Number of protected semiconductor outputs | 2 |
Number of protected contact energized outputs | 0 |
Fade-out possible | No |
Type of interface for safety communication | Other |
Type of switching output of the OSSD | Other |
Type of electric connection | Connector M12 |
Operation agent-safety class | Safety class 3 |
Detection power for test bodies | 500 |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Scope of delivery of the one-way system | Transmitter |
Max. output current at protected output | 500 |
With monitoring function downstream switching devices | Yes |
With restart blockage | Yes |
With muting function | No |
Override possible | No |
Time of reaction | 11 |
Reduced resolution | No |
Transmission range of the safety field | 8 |
Switching voltage of OSSD at state "high" | 24 |
Safety field height | 500 |
Type of safety according to IEC 61496-1 | 4 |
With beam coding | No |
Clock control possible | No |
Wavelength of the sensor | 950 |
Degree of protection (IP) | IP65 |
Resolution of the light curtain | 519.8 |
Width sensor | 52 |
Height of sensor | 0.6 |
Length of sensor | 57 |