Pluto D20
ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
2TLA020070R6400
7824702367
-
Discount code:
UNSPSC Code:
Customs code:
80080178
32151705
85364110
Safety PLC with Pluto safety bus and analogue inputs. Totally 20 I/O: 4 combined failsafe analogue and digital inputs + 4 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs.
Analogue input range 0-10V/4-20mA.
Width | 45 |
---|---|
Model | Compact |
Height | 84 |
Depth | 120 |
With display | Yes |
Suitable for safety functions | Yes |
Number of digital inputs | 16 |
Number of digital outputs | 12 |
Number of analogue inputs | 4 |
Number of analogue outputs | 0 |
Voltage type of supply voltage | DC |
Type of memory | FLASH |
Memory size | 128 |
Processing time (1K, binary operation) | 1 |
Supporting protocol for LON | No |
Number of HW-interfaces industrial Ethernet | 0 |
Number of HW-interfaces RS-232 | 1 |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 0 |
Number of HW-interfaces USB | 0 |
Number of HW-interfaces parallel | 0 |
Number of HW-interfaces other | 1 |
With optical interface | No |
Additional program memory possible | No |
Supporting protocol for TCP/IP | No |
Supporting protocol for ASI | No |
Supporting protocol for PROFIBUS | Yes |
Supporting protocol for CAN | Yes |
Supporting protocol for INTERBUS | No |
Supporting protocol for KNX | No |
Supporting protocol for Modbus | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for other bus systems | Yes |
Redundancy | Yes |
Rail mounting possible | Yes |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
System accessory | No |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Supporting protocol for SERCOS | No |
Supporting protocol for INTERBUS-Safety | No |
Category according to EN 954-1 | 4 |
Number of interfaces PROFINET | 0 |
Number of HW-interfaces Wireless | 0 |
Front build in possible | No |
Rack-assembly possible | No |
Wall mounting/direct mounting | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
IO link master | No |
Number of relay outputs | 2 |
Max. number of time switches | 256 |
Performance level according to EN ISO 13849-1 | Level e |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supply voltage AC 50 Hz | 0 - 0 |
Supply voltage AC 60 Hz | 0 - 0 |
Supply voltage DC | 24 - 24 |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |