S802S-C16 High Performance MCB

ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
2CCS862001R0164
7822215995
-
Discount code:
UNSPSC Code:
Customs code:
80080800060
39121614
85362020
The S802S-C16 is a 2-pole High Performance Circuit breaker with C-characteristic, with cage terminal and a rated current of 16 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S802S-C16 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S802S-C16 more comfortable. Due to the fast arc extinction of S802S-C16 your application will be secured.
Voltage typeAC
Built-in depth82.5
Rated current16
Rated voltage400
Frequency50 - 60
Release characteristicC
Rated insulation voltage Ui690
Current limiting class3
Over voltage category3
Pollution degree3
Width in number of modular spacings3
Degree of protection (IP)IP20
Number of protected poles2
Concurrently switching N-neutralNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50
Connectable conductor cross section multi-wired0 - 70
Ambient temperature during operating-25 - 60
Additional equipment possibleYes
Number of poles (total)2
Rated short-circuit breaking capacity Icn EN 60898 at 400 V25
Rated short-circuit breaking capacity Icn EN 60898 at 230 V25
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V50
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V50
Rated impulse withstand voltage Uimp8
;