S804N-C63 High Performance MCB
ABB
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}}
{{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}}
({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}}
(Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions
Product description
Type no.:
LM no.:
Own product no.:
2CCS894001R0634
7822216130
-
Discount code:
UNSPSC Code:
Customs code:
80080800060
39121614
85362090
The S804N-C63 is a 4-pole High Performance Circuit breaker with C-characteristic, with cage terminal and a rated current of 63 A. It is a current limiting device with a maximum breaking capacity of 36kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S804N-C63 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S804N-C63 more comfortable. Due to the fast arc extinction of S804N-C63 your application will be secured.
Voltage type | AC/DC |
---|---|
Built-in depth | 82.5 |
Rated current | 63 |
Rated voltage | 690 |
Frequency | 50 - 60 |
Release characteristic | C |
Rated insulation voltage Ui | 690 |
Current limiting class | 3 |
Over voltage category | 4 |
Pollution degree | 3 |
Width in number of modular spacings | 4 |
Degree of protection (IP) | IP20 |
Number of protected poles | 4 |
Concurrently switching N-neutral | No |
Suitable for flush-mounted installation | No |
Connectable conductor cross section solid-core | 0 - 50 |
Connectable conductor cross section multi-wired | 0 - 70 |
Ambient temperature during operating | -25 - 60 |
Additional equipment possible | Yes |
Number of poles (total) | 4 |
Rated short-circuit breaking capacity Icn EN 60898 at 400 V | 25 |
Rated short-circuit breaking capacity Icn EN 60898 at 230 V | 25 |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V | 36 |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V | 36 |
Rated impulse withstand voltage Uimp | 8 |