Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

Safety pos.switch with tumbler 3SE5312-0SD12

SIEMENS A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
3SE5312-0SD12
0424707510
-
Discount code:
UNSPSC Code:
Customs code:
8008041911137
39122205
85365080
Safety position switches with solenoid interlocking lock. force 2600n,5 appr. dir. metal housing,3x(m20x1.5) spring-locked, auxiliary release on front magnet voltage 115v ac, monitor. of actuator 2nc/1no, monitor. of magnet 2nc/1no
Material housingMetal
Suitable for safety functionsYes
Coating housingLacquered
With status indicationNo
Type of switching contactSlow-action switch
Type of interface for safety communicationNone
Type of electric connectionCable entry metrical
Explosion safety category for gasNone
Explosion safety category for dustNone
Construction type housingSpecial construction
Degree of protection (IP)IP66/IP67
Number of safety auxiliary contacts4
Type of interfaceNone
Rated control supply voltage Us magnet drive at AC 50 Hz115 - 115
Rated control supply voltage Us magnet drive at AC 60 Hz115 - 115
Rated operation current Ie at AC-15, 24 V6
Rated operation current Ie at DC-13, 125 V0.55
Rated operation current Ie at DC-13, 24 V3
Width sensor54.0
With escape releaseNo
Height of sensor43.5
Length of sensor185.0
Ambient temperature during operating-25 - 60
Guard locking force2600
Number of contacts as change-over contact0
Type of guard lockingQuiescent current principle
;