Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

Smart Home interface for Automation Systems Model ZIF5028

Logic Group A/S
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
ZIF5028
7867500568
-
Discount code:
UNSPSC Code:
Customs code:
80210777
39121801
85176200
The ZIF5028 DIN-rail module, which is built upon the wireless Z-Wave communication protocol, has 6 relay driven outputs and 6 digital inputs. The unit is a multi-purpose Z-Wave I/O module, which can be used for many applications. E.g. ZIF5028 provides the possibility to control other systems via the Z-Wave network, by utilizing the 6 outputs as a kind of hand-over function to another automation system. The relay outputs, which can be controlled from the Z-Wave network, is suitable for switching up to 6 pcs. 230Vac loads. In connection with simultaneous connection to SELV (Safety Extra Low Voltage) and 230Vac power circuits for relay outputs, relays must be considered as two groups, where the first group includes output 1 to 3 and the second group includes the outputs 4 to 6. This ensures complete separation between the SELV and 230Vac circuits. If one of the relays in the group is connected to a SELV circuit, the remaining outputs are not allowed to be connected to 230Vac or another circuit which is not a SELV circuit. For example, the relay outputs of the ZIF5028 module can be used to control the 230Vac power supply outlet, making it possible to turn on and disconnect the electrical outlets directly through the Z-Wave network. For safety reasons, however, it is recommended not to use the ZIF5028 to plug electrical outlets that are normally used for hazardous tools and machinery. The 6 digital inputs of the ZIF5028 are useful for various purposes, where potential-free contacts, or Open Collector outputs, can be connected. The inputs can be configured to different trigger modes; leading edge, trailing edge or level triggered. The ZIF5028's inputs can be programmed to control other Z-Wave devices when the inputs are activated, by sending Z-Wave commands over the Z-Wave network to e.g. Z-Wave relay modules, dimmer units etc. ZIF5028 allows sending different types of Z-Wave commands by utilizing the different association groups for the 6 inputs. In addition, the ZIF5028 also acts as a repeater, thus extending the range of the Z-Wave network. By default, the ZIF5028's inputs and outputs are set to operate as toggle-relays. Input 1 controls the output 1, input 2 controls the output 2, etc. This functionality can be modified via the configuration parameters 3-8 and 13-18
BrandLogic Group
;