Log-in lemu.dk

Your access to more than 300,000 different products and a wide range of services

Enter your e-mail address and have your password sent to you:

Cancel
en

Zelio control relay for 3-phase detection of undervoltage and phase-fault 1C/O 5A 3x230-400VAC

Schneider Electric
{{StockInfo.NotAllowedReason}}
{{stck.StockInfo.RemoteStockLocation.DisplayName}} {{stck.StockInfo.RemoteStockLocation.Amount|number}} {{stck.StockInfo.RemoteStockLocation.Uom}} ({{stck.StockInfo.RemoteStockLocation.DeliveryTimeTxt}})
{{stck.StockInfo.CentralStockLocation.Amount|number}} {{stck.StockInfo.CentralStockLocation.Uom}} {{stck.StockInfo.CentralStockLocation.DisplayName}}
{{stck.StockInfo.CentralStockLocation.DisplayName}} (In stock)
{{stck.StockInfo.CentralStockLocation.DisplayName}} (Not in stock)
{{stck.StockInfo.CentralStockLocation.DeliveryTimeTxt}}
[{{stck.StockInfo.PrimaryStockLocation.DeliveryTimeTxt}}]
{{stck.StockInfo.NotCentralStockDeliveryTimeMsg}}
{{stck.StockInfo.SecondaryStockLocation.DisplayName}}: {{stck.StockInfo.SecondaryStockLocation.Amount|number}} {{stck.StockInfo.SecondaryStockLocation.Uom}}
Special return conditions

Product description

Type no.:
LM no.:
Own product no.:
RM17TU00
7523006209
-
Discount code:
UNSPSC Code:
Customs code:
80080463030
39122332
85371098
Zelio RM17 is a compact series of control relays which is easy to mount on a DIN-rail. The relays are available for either 1 phase or 3 phase applications and are able to measure the voltage, current, phase-loss, phase-sequence and asymmetry between phases. With a width of only 17,5 mm they only take up a very limited space on the DIN-rail and they also fit behind the cover of a standard panel. RM17TU00 is a control relay for 3-phase applications. The relay is measuring the typical failures which can occur in a 3-phase application (phase-loss, phase-sequence and undervoltage). The 3 phases are mounted on the supply L1, L2 and L3 terminals on the top of the relay and the output contacts are located in the bottom. The output is activated instantanious when powered on if all 3 phases are present and mounted in the right order. On the front of the relay are 3 dials for setting up the relay: The first dial adjust the voltage between the 3 phases in the application (208, 220, 380, 400, 415, 440 or 480VAC). The second dial adjust the time delay on the output from 0,1..10 seconds in case of an undervoltage fault. The third dial adjust the maximum allowed undervoltage and the value can be set between 2..20% of the voltage range. If a phase-loss or phase-sequence fault is detected, the output instantly changes state and if an undervoltage fault is detected, the output changes state after the delay time set on the dial. The control relay has a 1 C/O output contact with a maximum load of 5A. RM17TU00 is self powered through the measuring terminals on the top and the supply voltage can be from 183 to 528 VAC. The relay can be used with both 50Hz and 60Hz supply voltage. On the front of the relay is 2 LED's for indication of the relay status. The green LED indicates that the supply is present and the yellow LED indicates the status of the relay output.

None

;